INGV INGV OCEANO GROUP BO ERDDAP
Easier access to scientific data
| ?    
Brought to you by INGV OCEANO GROUP    

ERDDAP > tabledap > Data Access Form ?

Dataset Title:  Southern Tyrrhenian Sea GEOSTAR- SN-3 2004 Current meter data Subscribe RSS
Institution:  Istituto Nazionale Geofisica e Vulcanologia - Sez. Roma2   (Dataset ID: ORION_2_Current)
Information:  Summary ? | License ? | FGDC | ISO 19115 | Metadata | Background (external link) | Subset | Make a graph
 
Variable ?   Optional
Constraint #1 ?
Optional
Constraint #2 ?
   Minimum ?
   or a List of Values ?
   Maximum ?
 
 time (time of measurements, UTC) ?          2004-06-13T13:00:00Z    2005-02-02T12:59:59Z
  < slider >
 depth (depth of measurements, m) ?      
   - +  ?
  < slider >
 longitude (degrees_east) ?      
   - +  ?
  < slider >
 latitude (degrees_north) ?      
   - +  ?
  < slider >
 EWCT (Centimetres per seconds) ?          -15.87    16.36
 NSCT (Centimetres per seconds) ?          -15.85    19.79
 UVCT (Centimetres per seconds) ?          -17.22    15.35
 TILTX (degrees) ?          -0.699    0.1
 TILTY (degrees) ?          -0.955    -0.1
 HEAD (Heading, degrees) ?          83.55    86.4
 TEMP (temperature, degree_C) ?          13.31    13.488
 PRES (pressure, decibar) ?          3387.65    3399.7
 TIME_QC (TIME quality control flags) ?      
   - +  ?
 DEPTH_QC (DEPTH quality control flags) ?      
   - +  ?
 POSITION_QC ?      
   - +  ?
 EWCT_QC (EWCT quality control flags) ?          1    9
 NSCT_QC (NSCT quality control flags) ?          1    9
 UVCT_QC (UVCT quality control flags) ?          1    9
 
Server-side Functions ?
 distinct() ?
? ("Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.")

File type: (more information)

(Documentation / Bypass this form ? )
 
(Please be patient. It may take a while to get the data.)


 

The Dataset Attribute Structure (.das) for this Dataset

Attributes {
 s {
  time {
    String _CoordinateAxisType "Time";
    Float64 actual_range 1.0871316e+9, 1.1073491995e+9;
    String ancillary_variables "TIME_QC";
    String axis "T";
    String cf_role "timeseries_id";
    String ioos_category "Time";
    String long_name "time of measurements";
    String sdn_P02_urn "SDN:P02::AYMD";
    String sdn_parameter_name "Elapsed time relative to 1970-01-01T00:00:00Z";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/ELTMEP01/";
    String sdn_parameter_urn "SDN:P01::ELTMEP01";
    String sdn_uom_name "Seconds";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPTBB/";
    String sdn_uom_urn "SDN:P06::UTBB";
    String standard_name "time";
    String time_origin "01-JAN-1970 00:00:00";
    String units "seconds since 1970-01-01T00:00:00Z";
  }
  depth {
    String _CoordinateAxisType "Height";
    String _CoordinateZisPositive "down";
    Float32 actual_range 3314.0, 3314.0;
    String ancillary_variables "DEPTH_QC";
    String axis "Z";
    Float64 colorBarMaximum 8000.0;
    Float64 colorBarMinimum -8000.0;
    String colorBarPalette "TopographyDepth";
    String ioos_category "Location";
    String long_name "depth of measurements";
    String positive "down";
    String sdn_P02_urn "SDN:P02::AHGT";
    String sdn_parameter_name "Depth (spatial coordinate) relative to water surface in the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/ADEPZZ01/";
    String sdn_parameter_urn "SDN:P01::ADEPZZ01";
    String sdn_uom_name "Meters";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/ULAA/";
    String sdn_uom_urn "SDN:P06::ULAA";
    String standard_name "depth";
    String units "m";
  }
  longitude {
    String _CoordinateAxisType "Lon";
    Float32 actual_range 14.32611, 14.32611;
    String ancillary_variables "POSITION_QC";
    String axis "X";
    String ioos_category "Location";
    String long_name "longitude of measurements";
    String sdn_P02_urn "SDN:P02::ALAT";
    String sdn_parameter_name "Longitude east";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/ALONZZ01/";
    String sdn_parameter_urn "SDN:P01::ALONZZ01";
    String sdn_uom_name "Degrees east";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/DEGE/";
    String sdn_uom_urn "SDN:P06::DEGE";
    String standard_name "longitude";
    String units "degrees_east";
  }
  latitude {
    String _CoordinateAxisType "Lat";
    Float32 actual_range 39.48806, 39.48806;
    String ancillary_variables "POSITION_QC";
    String axis "Y";
    Float64 colorBarMaximum 90.0;
    Float64 colorBarMinimum -90.0;
    String ioos_category "Location";
    String long_name "latitude of measurements";
    String sdn_P02_urn "SDN:P02::ALAT";
    String sdn_parameter_name "Longitude north";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/ALATZZ01/";
    String sdn_parameter_urn "SDN:P01::ALATZZ01";
    String sdn_uom_name "Degrees north";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/DEGN/";
    String sdn_uom_urn "SDN:P06::DEGN";
    String standard_name "latitude";
    String units "degrees_north";
  }
  EWCT {
    Float32 _FillValue -999.0;
    Float32 actual_range -15.87, 16.36;
    String ancillary_variables "EWCT_QC";
    Float64 colorBarMaximum 0.5;
    Float64 colorBarMinimum -0.5;
    String long_name "eastward sea water velocity";
    String sdn_P02_urn "SDN:P02::RFVL";
    String sdn_parameter_name "Eastward velocity of water current in the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LCEWZZ01/";
    String sdn_parameter_urn "SDN:P01::LCEWZZ01";
    String sdn_uom_name "Centimetres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVBB/";
    String sdn_uom_urn "SDN:P06::UVBB";
    String sensor_manufacturer "Falmouth Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0324/";
    String sensor_manufacturer_urn "SDN:L35::MAN0324";
    String sensor_model "Falmouth 3D-ACM 3 axis acoustic current meter";
    String sensor_mount "mounted_on_seafloor_structure";
    String sensor_orientation "horizontal";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL2132/";
    String sensor_SeaVoX_L22_code "SDN::L22::TOOL2132";
    String sensor_serial_number "1647A";
    String sensor_type_name "current profilers";
    String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/114/";
    String standard_name "eastward_sea_water_velocity";
    String units "Centimetres per seconds";
  }
  NSCT {
    Float32 _FillValue -999.0;
    Float32 actual_range -15.85, 19.79;
    String ancillary_variables "NSCT";
    Float64 colorBarMaximum 0.5;
    Float64 colorBarMinimum -0.5;
    String long_name "northward sea water velocity";
    String sdn_P02_urn "SDN:P02::RFVL";
    String sdn_parameter_name "Northward velocity of water current in the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LCNSZZ01/";
    String sdn_parameter_urn "SDN:P01::LCNSZZ01";
    String sdn_uom_name "Centimetres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVBB/";
    String sdn_uom_urn "SDN:P06::UVBB";
    String sensor_manufacturer "Falmouth Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0324/";
    String sensor_manufacturer_urn "SDN:L35::MAN0324";
    String sensor_model "Falmouth 3D-ACM 3 axis acoustic current meter";
    String sensor_mount "mounted_on_seafloor_structure";
    String sensor_orientation "horizontal";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL2132/";
    String sensor_SeaVoX_L22_code "SDN::L22::TOOL2132";
    String sensor_serial_number "1647A";
    String sensor_type_name "current profilers";
    String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/114/";
    String standard_name "northward_sea_water_velocity";
    String units "Centimetres per seconds";
  }
  UVCT {
    Float32 _FillValue -999.0;
    Float32 actual_range -17.22, 15.35;
    String ancillary_variables "NSCT";
    Float64 colorBarMaximum 0.5;
    Float64 colorBarMinimum -0.5;
    String long_name "upward sea water velocity";
    String sdn_P02_urn "SDN:P02::LRZA";
    String sdn_parameter_name "Upward velocity of water current in the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/LRZAZZZZ/";
    String sdn_parameter_urn "SDN:P01::LRZAZZZZ";
    String sdn_uom_name "Centimetres per second";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UVBB/";
    String sdn_uom_urn "SDN:P06::UVBB";
    String sensor_manufacturer "Falmouth Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0324/";
    String sensor_manufacturer_urn "SDN:L35::MAN0324";
    String sensor_model "Falmouth 3D-ACM 3 axis acoustic current meter";
    String sensor_mount "mounted_on_seafloor_structure";
    String sensor_orientation "horizontal";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL2132/";
    String sensor_SeaVoX_L22_code "SDN::L22::TOOL2132";
    String sensor_serial_number "1647A";
    String sensor_type_name "current profilers";
    String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/114/";
    String standard_name "upward_sea_water_velocity";
    String units "Centimetres per seconds";
  }
  TILTX {
    Float32 _FillValue -999.0;
    Float32 actual_range -0.699, 0.1;
    String long_name "Tilt x";
    String sdn_P02_urn "SDN:P02::SAGE";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/";
    String sdn_parameter_urn "SDN:P01::";
    String sdn_uom_name "Degrees";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/";
    String sdn_uom_urn "SDN:P06::UAAA";
    String units "degrees";
  }
  TILTY {
    Float32 _FillValue -999.0;
    Float32 actual_range -0.955, -0.1;
    String long_name "Tilt y";
    String sdn_P02_urn "SDN:P02::SAGE";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/";
    String sdn_parameter_urn "SDN:P01::";
    String sdn_uom_name "Degrees";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/";
    String sdn_uom_urn "SDN:P06::UAAA";
    String units "degrees";
  }
  HEAD {
    Float32 _FillValue -999.0;
    Float32 actual_range 83.55, 86.4;
    String long_name "Heading";
    String sdn_P02_urn "SDN:P02::HEAD";
    String sdn_parameter_name "Orientation (horizontal) of measurement platform relative to magnetic north {heading} by compass";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/HEADCMMG";
    String sdn_parameter_urn "SDN:P01::HEADCMMG";
    String sdn_uom_name "Degrees";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UAAA/";
    String sdn_uom_urn "SDN:P06::UAAA";
    String sensor_manufacturer "Falmouth Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0324/";
    String sensor_manufacturer_urn "SDN:L35::MAN0324";
    String sensor_model "Falmouth 3D-ACM 3 axis acoustic current meter";
    String sensor_mount "mounted_on_seafloor_structure";
    String sensor_orientation "horizontal";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL2132/";
    String sensor_SeaVoX_L22_code "SDN::L22::TOOL2132";
    String sensor_serial_number "1647A";
    String sensor_type_name "current profilers";
    String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/114/";
    String units "degrees";
  }
  TEMP {
    Float32 _FillValue -999.0;
    Float32 actual_range 13.31, 13.488;
    String ancillary_variables "TEMP_QC";
    Float64 colorBarMaximum 32.0;
    Float64 colorBarMinimum 0.0;
    String long_name "temperature";
    String sdn_P02_urn "SDN:P02::TEMP";
    String sdn_parameter_name "Temperature of the water body";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/TEMPPR01/";
    String sdn_parameter_urn "SDN:P01::TEMPPR01";
    String sdn_uom_name "Degrees Celsius";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPAA/";
    String sdn_uom_urn "SDN:P06::UPAA";
    String sensor_manufacturer "Falmouth Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0324/";
    String sensor_manufacturer_urn "SDN:L35::MAN0324";
    String sensor_model "Falmouth 3D-ACM 3 axis acoustic current meter";
    String sensor_mount "mounted_on_seafloor_structure";
    String sensor_orientation "horizontal";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL2132/";
    String sensor_SeaVoX_L22_code "SDN::L22::TOOL2132";
    String sensor_serial_number "1647A";
    String sensor_type_name "current profilers";
    String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/114/";
    String standard_name "sea_water_temperature";
    String units "degree_C";
  }
  PRES {
    Float32 _FillValue -999.0;
    Float32 actual_range 3387.65, 3399.7;
    String ancillary_variables "PRES_QC";
    Float64 colorBarMaximum 5000.0;
    Float64 colorBarMinimum 0.0;
    String long_name "pressure";
    String sdn_P02_urn "SDN:P02::ASLV";
    String sdn_parameter_name "Pressure (measured variable) exerted by the water body plus atmosphere by fixed in-situ pressure sensor";
    String sdn_parameter_uri "https://vocab.nerc.ac.uk/collection/P01/current/PRSTPS01/";
    String sdn_parameter_urn "SDN:P01::PRSTPS01";
    String sdn_uom_name "Decibars";
    String sdn_uom_uri "https://vocab.nerc.ac.uk/collection/P06/current/UPDB/";
    String sdn_uom_urn "SDN:P06::UPDB";
    String sensor_manufacturer "Falmouth Scientific";
    String sensor_manufacturer_uri "https://vocab.nerc.ac.uk/collection/L35/current/MAN0324/";
    String sensor_manufacturer_urn "SDN:L35::MAN0324";
    String sensor_model "Falmouth 3D-ACM 3 axis acoustic current meter";
    String sensor_mount "mounted_on_seafloor_structure";
    String sensor_orientation "horizontal";
    String sensor_reference "https://vocab.nerc.ac.uk/collection/L22/current/TOOL2132/";
    String sensor_SeaVoX_L22_code "SDN::L22::TOOL2132";
    String sensor_serial_number "1647A";
    String sensor_type_name "current profilers";
    String sensor_type_uri "https://vocab.nerc.ac.uk/collection/L05/current/114/";
    String standard_name "sea_water_pressure";
    String units "decibar";
  }
  TIME_QC {
    Byte _FillValue -127;
    String _Unsigned "false";
    Byte actual_range 1, 1;
    Float64 colorBarMaximum 10.0;
    Float64 colorBarMinimum 0.0;
    String conventions "OceanSITES QC Flags";
    String flag_meanings "unknown, good_data, probably_good_data, potentially_correctable_bad_data,bad_data, nominal_value, interpolated_value, missing_value";
    String flag_values "0, 1, 2, 3, 4, 7, 8, 9";
    String long_name "TIME quality control flags";
  }
  DEPTH_QC {
    Byte _FillValue -127;
    String _Unsigned "false";
    Byte actual_range 1, 1;
    Float64 colorBarMaximum 10.0;
    Float64 colorBarMinimum 0.0;
    String conventions "OceanSITES QC Flags";
    String flag_meanings "unknown, good_data, probably_good_data, potentially_correctable_bad_data,bad_data, nominal_value, interpolated_value, missing_value";
    String flag_values "0, 1, 2, 3, 4, 7, 8, 9";
    String long_name "DEPTH quality control flags";
    String standard_name "depth";
  }
  POSITION_QC {
    Byte _FillValue -127;
    String _Unsigned "false";
    Byte actual_range 1, 1;
    Float64 colorBarMaximum 10.0;
    Float64 colorBarMinimum 0.0;
    String conventions "OceanSITES QC Flags";
    String flag_meanings "unknown, good_data, probably_good_data, potentially_correctable_bad_data,bad_data, nominal_value, interpolated_value, missing_value";
    String flag_values "0, 1, 2, 3, 4, 7, 8, 9";
    String long_name "POSITION quality control flags";
  }
  EWCT_QC {
    Byte _FillValue -127;
    String _Unsigned "false";
    Byte actual_range 1, 9;
    Float64 colorBarMaximum 10.0;
    Float64 colorBarMinimum 0.0;
    String conventions "OceanSITES QC Flags";
    String flag_meanings "unknown, good_data, probably_good_data, potentially_correctable_bad_data,bad_data, nominal_value, interpolated_value, missing_value";
    String flag_values "0, 1, 2, 3, 4, 7, 8, 9";
    String long_name "EWCT quality control flags";
  }
  NSCT_QC {
    Byte _FillValue -127;
    String _Unsigned "false";
    Byte actual_range 1, 9;
    Float64 colorBarMaximum 10.0;
    Float64 colorBarMinimum 0.0;
    String conventions "OceanSITES QC Flags";
    String flag_meanings "unknown, good_data, probably_good_data, potentially_correctable_bad_data,bad_data, nominal_value, interpolated_value, missing_value";
    String flag_values "0, 1, 2, 3, 4, 7, 8, 9";
    String long_name "NSCT quality control flags";
  }
  UVCT_QC {
    Byte _FillValue -127;
    String _Unsigned "false";
    Byte actual_range 1, 9;
    Float64 colorBarMaximum 10.0;
    Float64 colorBarMinimum 0.0;
    String conventions "OceanSITES QC Flags";
    String flag_meanings "unknown, good_data, probably_good_data, potentially_correctable_bad_data,bad_data, nominal_value, interpolated_value, missing_value";
    String flag_values "0, 1, 2, 3, 4, 7, 8, 9";
    String long_name "UVCT quality control flags";
  }
 }
  NC_GLOBAL {
    String cdm_data_type "TimeSeries";
    String cdm_timeseries_variables "depth,latitude,longitude,time";
    String Conventions "OceanSITES-1.5,SeaDataNet_1.0,COARDS, CF-1.6, ACDD-1.3";
    String creator_name "Istituto Nazionale Geofisica e Vulcanologia - Sez. Roma2";
    String creator_url "www.moist.it";
    String data_mode "D";
    String data_type "OceanSITES time-series data";
    Float64 Easternmost_Easting 14.32611;
    String emso_facility "Southern Tyrrhenian Sea";
    String featureType "TimeSeries";
    String format_version "1.4";
    Float64 geospatial_lat_max 39.48806;
    Float64 geospatial_lat_min 39.48806;
    String geospatial_lat_units "degrees_north";
    Float64 geospatial_lon_max 14.32611;
    Float64 geospatial_lon_min 14.32611;
    String geospatial_lon_units "degrees_east";
    Float64 geospatial_vertical_max 3314.0;
    Float64 geospatial_vertical_min 3314.0;
    String geospatial_vertical_positive "down";
    String geospatial_vertical_units "m";
    String history 
"2025-03-10T11:05:49Z (local files)
2025-03-10T11:05:49Z http://oceano.bo.ingv.it/erddap/tabledap/ORION_2_Current.html";
    String infoUrl "http://www.moist.it/sites/southern_tyrrhenian_sea/3/ORION2/current_meter/86/qc";
    String institution "Istituto Nazionale Geofisica e Vulcanologia - Sez. Roma2";
    String institution_edmo_code "3917";
    String institution_edmo_uri "https://edmo.seadatanet.org/report/3917";
    String institution_ror_uri "https://ror.org/00qps9a02";
    String keywords "circulation, control, current, currents, data, depth, DEPTH_QC, earth, Earth Science > Oceans > Ocean Circulation > Ocean Currents, Earth Science > Oceans > Ocean Pressure > Water Pressure, Earth Science > Oceans > Ocean Temperature > Water Temperature, eastward, eastward_sea_water_velocity, ewct, EWCT_QC, flags, geofisica, geostar, geostar-, HEAD, heading, istituto, latitude, longitude, meter, nazionale, northward, northward_sea_water_velocity, nsct, NSCT_QC, ocean, oceans, orientation, position, POSITION_QC, PRES, pressure, quality, roma2, science, sea, sea water speed, sea water velocity, sea_water_pressure, sea_water_temperature, seawater, sez, sn-3, southern, TEMP, temperature, tilt, TILTX, TILTY, time, TIME_QC, tyrrhenian, upward, upward_sea_water_velocity, uvct, UVCT_QC, velocity, vulcanologia, water";
    String keywords_vocabulary "GCMD Science Keywords";
    String license "CC-BY-4.0";
    String license_uri "https://spdx.org/licenses/CC-BY-4.0.json";
    Float64 Northernmost_Northing 39.48806;
    String principal_investigator "Beatrice Giambenedetti";
    String principal_investigator_email "beatrice.giambenedetti@ingv.it";
    String project "ORION1-GEOSTAR3";
    String site_code "GEOSTAR- SN-3";
    String source "fixed benthic node";
    String sourceUrl "(local files)";
    Float64 Southernmost_Northing 39.48806;
    String standard_name_vocabulary "CF Standard Name Table v70";
    String subsetVariables "depth, longitude, latitude, TIME_QC, DEPTH_QC, POSITION_QC";
    String summary "Falmouth 3D-ACM 3 axis acoustic current meter, a high-accuracy meter with vector-averaged current speed and direction.";
    String time_coverage_end "2005-02-02T12:59:59Z";
    String time_coverage_start "2004-06-13T13:00:00Z";
    String title "Southern Tyrrhenian Sea GEOSTAR- SN-3 2004 Current meter data";
    String update_interval "void";
    Float64 Westernmost_Easting 14.32611;
  }
}

 

Using tabledap to Request Data and Graphs from Tabular Datasets

tabledap lets you request a data subset, a graph, or a map from a tabular dataset (for example, buoy data), via a specially formed URL. tabledap uses the OPeNDAP (external link) Data Access Protocol (DAP) (external link) and its selection constraints (external link).

The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.

Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names, followed by a collection of constraints (e.g., variable<value), each preceded by '&' (which is interpreted as "AND").

For details, see the tabledap Documentation.


 
ERDDAP, Version 2.18
Disclaimers | Privacy Policy | Contact